Vertical oscillation incubators are widely used in laboratories in scientific research, teaching, medicine, and other fields, providing convenience for microbial culture, cell culture, and biochemical experiments.
※ 1. Pioneering cutting-edge USB data storage system. Automatically record and store test process data throughout the entire process.
※ 2. The USB flash drive records experimental data throughout the entire process (including temperature, speed, and time).
※ 3. Download data automatically and list it into a map for saving and printing. Simply click the mouse to easily replay the experimental process. Facilitating the optimization of reaction conditions, screening of experimental methods, and confirmation of the experimental process.
※ 4. Multi stage speed, temperature, and time control system. Multiple different speed, temperature, and time experimental modes can be set at once, and the operating mode will automatically switch during operation.
※ 5. When starting at ultra-low speed, if the speed loses control, it will automatically lock and the starting speed can be adjusted. Unique dynamic balancing design ensures smooth operation
※ 6. The silent fan design, forced convection method, and unique air duct design ensure good temperature uniformity.
※ 7. Users can freely set three operation modes: forward rotation, reverse rotation, and alternating forward and backward rotation.
※ 8. LCD display, temperature, time, and speed are displayed on the same interface.
9. Fault self diagnosis function, displaying the fault location and fault code when a fault occurs, can quickly and conveniently identify and solve problems.
10. High precision speed control: PID feedback control to avoid losses caused by motor overheating and shutdown due to long-term low-speed operation.
11. Equipped with high-quality servo motors, precise speed control, good high and low speed performance, and strong stability. The minimum speed of 1rpm can be customized according to customer needs.
12. Equipped with filter magnetic rings to reduce interference from external and internal wavelengths on the stability of the machine.
13. High precision temperature control: PID feedback control with temperature deviation alarm function.
14. The unique drive system ensures smooth, stable, durable, and reliable operation of the machine.
15. Intelligent alarm environment scanning microprocessor controller. It has functions such as door opening self stop protection, fault self diagnosis, and safety alarm.
16. The operating parameters can be memorized and protected. The power supply unexpectedly loses power, and automatically resumes operation according to the original set program after receiving a call.
17. You can set a reservation to start the machine, and the machine will automatically run when the reservation time is reached.
18. Unique automatic protection device for motor overheating and temperature runaway.
19. Can run on schedule or continuously, displaying remaining time or running time.
20. The unique slow start design prevents the splashing of shaking bottle liquid caused by sudden start, effectively ensuring the accuracy of quantitative experiments.
21. Optional humidification shaker, humidity control range: -95% ambient humidity (working temperature in the warehouse between 20-60 ℃), model: HNY-1102S
22. Optional high-temperature shaker with a maximum temperature of 80 ℃. Model: HNY-1102W
23. Equipped with a transparent insert frame, it is convenient for customers to place experimental record cards. The insert frame can be disassembled and installed at any time according to customer needs, making it easy to use.
【Specification】
Product Model | HNY-1102 |
Control method | P.I.D microcomputer processing chip |
Convection mode | Forced convection |
Oscillation mode | Convolute |
Display mode | LCD Display |
Download Processing | USB Data Port Download |
Control system | Standard mode; Static mode; Continuous mode; Program control mode (multi segment temperature, speed, time control) |
Cyclotron frequency range (rpm) | 0; 20-350rpm (can be used for static cultivation, forward and reverse rotation, or alternating operation) |
Cyclotron frequency accuracy | ± 1rpm |
Swinging amplitude of the shaking plate (mm) | Φ 26mm (customizable for Φ 35 (20-250rpm), Φ 50 (20-200rpm)) |
Maximum configuration (flask clamp) | 100ml * 100 or 250ml * 56 or 500ml * 44 or 1000ml * 24 |
Maximum configuration (adhesive board) | 100ml * 120 or 250ml * 70 or 500ml * 44 or 1000ml * 24 |
Standard Configuration | 250ml * 28 500ml * 22 |
Tray size | 710 * 455mm |
Timing range | 0-9999h/min (can run continuously without timing) |
Temperature control range | Environmental temperature+5-65 ℃ |
Temperature control accuracy | ± 0.1 ℃ |
Temperature uniformity (° C) | ± 0.5 (37 ° C, effective working surface) |
Temperature fluctuation (° C) | ≤ 0.1 (37 ℃) |
Number of trays | 2 pieces |
Dimensions | 950*700*1280mm |
Capacity | 335 L |
Power | 900 W |
Power supply | AC220 ± 10% 50Hz |
Accessory functions | Ultra low speed start, adjustable start speed, automatic overspeed protection, monitoring timer, parameter memory, incoming call recovery, upper and lower limit over temperature sound and light alarm, automatic door opening stop, lighting, UV disinfection function (optional), parameter setting viewing, temperature monitoring and environmental temperature correction. |
Fil the form and send us your message.Get in touch with PAULAIR and find a specialized consultant for you !