Safety cabinet is the main isolation equipment used in laboratory, which can prevent the diffusion of harmful suspended particles and provide protection for experimenters, experimental materials and environment. It is safely applied to the operation of highly dangerous microorganisms, toxic substances and radioactive oligonucleotides.
86-15688870591
cedric@cedriccn.com
Product Features:
·Air curtain isolation design to prevent internal and external cross contamination. (Negative pressure type)
·The upper and lower glass doors are equipped with height limit alarm to prompt the operator to use them correctly.
·Special filters are set up at the exhaust to control pollution discharge.
·Equipped with a dedicated waterproof socket to provide great convenience for the operator.
·LED LCD panel control can effectively observe the size of the instrument's descending airflow and suction wind speed at any time.
·The experimental area adopts high quality 304 stainless steel, and the working area is equipped with 2KW spare socket to provide convenience for operators.
·The isolation operation surface is 10° inclined design, which is ergonomic and comfortable to operate.
Product Specification:
Model | BSC-1000A2 | BSC-1300A2 | BSC-1600A2 |
External size(W*D*H) | 1200*800*2120mm | 1500*800*2120mm | 1800*800*2120mm |
Internal size(W*D*H) | 1000*700*600mm | 1300*700*600mm | 1600*700*600mm |
Purification efficiency | Level 100 (U.S. federal standard 209E) The 100 stage(America federal standard 209E) | ||
Average air velocity | 0.25-0.5m/s | ||
Front inflow air | ≥0.5m/s | ||
Power | 0.8KW | ||
Average number of colonies | ≤ 0.5 per dish hour (A/dish/hour) | ||
Noise | ≤65dB(A) | ||
Vibration/half peak amplitude | ≤3μm(X·Y·Z) | ||
Power supply | 220V 50HZ | ||
Air intake filter size Filter size(L*W*H) | 980*490*50mm | 1280*490*50mm | 1580*490*50mm |
Size of air vents and filters Filter size(L*W*H) | 480*380*50mm | 780*380*50mm | 1080*380*50mm |
Lighting lamp (LED)/ sterilizing lamp (T5 integrated) Fluorescent lamp/UV lamp | 21W×②/20W×① | 28W×②/30W×① | 28W×②/30W×① |
Air outlet direction Wind direction | Top to Top φ300mm | ||
Filter efficiency Air tightness | 99.99≤E≤99.999 | ||
illumination | ≥700LX | ||
Packing size | 1300*900*2200mm | 1600*900*2200mm | 2000*900*2200mm |
Weight | 160kg/280kg | 180kg/290kg | 200kg/300kg |
Characteristic:
| 1. A new LED LCD panel is configured; it can display the instrument start time and operation time; it can also display the descending airflow and suction wind speed; it is equipped with a high-efficiency filter replacement reminder function and a one-button sterilization timer function of UV lamp, which can be quickly set in 15 minutes, 30 minutes and 60 minutes. |
| 2. Configure the central air conditioning fan of Yilida listed in China to ensure stable air volume of the instrument. |
| 3. The movable table and the all-stainless-iron inner cavity are designed with U-shaped surrounding design, which ensures that the table surface of the experimental area is beautiful, clean and bright, and is not easy to rust or scratch. The table surface is made of inclined slope, which can ensure the normal inhalation speed of the instrument without using the hand support frame, thus solving the arm fatigue of the operator. |
| 4. The integrated LED lamp frame and UV lamp frame are configured in the operation area to facilitate the later insertion, removal and replacement of the experimenters. |
| 5. The integrated LED lamp frame and UV lamp frame are configured in the operation area to facilitate the later insertion, removal and replacement of the experimenters. |
| 6. The ultra-high efficiency filter used in the instrument is U15 grade, with double-sided mesh reinforcement, which not only guarantees the safety of both sides of the filter paper, but also greatly improves the strength of the high efficiency filter. |
Fil the form and send us your message.Get in touch with PAULAIR and find a specialized consultant for you !