Tel:86-15688870591 E-mail:cedric@cedriccn.com
Class II A2 Biological Safety Cabinet
Class II A2 Biological Safety Cabinet

Safety cabinet is the main isolation equipment used in laboratory, which can prevent the diffusion of harmful suspended particles and provide protection for experimenters, experimental materials and environment. It is safely applied to the operation of highly dangerous microorganisms, toxic substances and radioactive oligonucleotides.

86-15688870591
cedric@cedriccn.com
Description

Product Features:

·Air curtain isolation design to prevent internal and external cross contamination. (Negative pressure type)

·The upper and lower glass doors are equipped with height limit alarm to prompt the operator to use them correctly.

·Special filters are set up at the exhaust to control pollution discharge.

·Equipped with a dedicated waterproof socket to provide great convenience for the operator.

·LED LCD panel control can effectively observe the size of the instrument's descending airflow and suction wind speed at any time.

·The experimental area adopts high quality 304 stainless steel, and the working area is equipped with 2KW spare socket to provide convenience for operators.

·The isolation operation surface is 10° inclined design, which is ergonomic and comfortable to operate.


Product Specification:

Model

BSC-1000A2

BSC-1300A2

BSC-1600A2

External size(W*D*H)

1200*800*2120mm

1500*800*2120mm

1800*800*2120mm

Internal size(W*D*H)

1000*700*600mm

1300*700*600mm

1600*700*600mm

Purification efficiency

Level 100 (U.S. federal standard 209E) The 100 stageAmerica federal standard 209E

Average air velocity

0.25-0.5m/s

Front inflow air

≥0.5m/s

Power

0.8KW

Average number of colonies

≤ 0.5 per dish hour (A/dish/hour)

Noise

≤65dBA

Vibration/half peak amplitude

≤3μmX·Y·Z

Power supply

220V 50HZ

Air intake filter size

Filter size(L*W*H)

980*490*50mm

1280*490*50mm

1580*490*50mm

Size of air vents and filters

Filter size(L*W*H)

480*380*50mm

780*380*50mm

1080*380*50mm

Lighting lamp (LED)/

sterilizing lamp (T5 integrated)

Fluorescent lamp/UV lamp

21W×②/20W×①

28W×②/30W×①

28W×②/30W×①

Air outlet direction

Wind direction

Top to Top φ300mm

Filter efficiency

Air tightness

99.99≤E≤99.999

illumination

≥700LX

Packing size

1300*900*2200mm

1600*900*2200mm

2000*900*2200mm

Weight

160kg/280kg

180kg/290kg

200kg/300kg


 Characteristic:

图片2 

1. A new LED LCD panel is configured; it can display the instrument start time and operation time; it can also display the descending airflow and suction wind speed; it is equipped with a high-efficiency filter replacement reminder function and a one-button sterilization timer function of UV lamp, which can be quickly set in 15 minutes, 30 minutes and 60 minutes.

图片3 

2. Configure the central air conditioning fan of Yilida listed in China to ensure stable air volume of the instrument.

图片4 

3. The movable table and the all-stainless-iron inner cavity are designed with U-shaped surrounding design, which ensures that the table surface of the experimental area is beautiful, clean and bright, and is not easy to rust or scratch. The table surface is made of inclined slope, which can ensure the normal inhalation speed of the instrument without using the hand support frame, thus solving the arm fatigue of the operator.

图片5 

4. The integrated LED lamp frame and UV lamp frame are configured in the operation area to facilitate the later insertion, removal and replacement of the experimenters.

图片6 

5. The integrated LED lamp frame and UV lamp frame are configured in the operation area to facilitate the later insertion, removal and replacement of the experimenters.

图片7 

6. The ultra-high efficiency filter used in the instrument is U15 grade, with double-sided mesh reinforcement, which not only guarantees the safety of both sides of the filter paper, but also greatly improves the strength of the high efficiency filter.