Tel:86-15688870591 E-mail:cedric@cedriccn.com
Fluorescence Fully Automated Chemiluminescence Imaging System CD-6000F
Fluorescence Fully Automated Chemiluminescence Imaging System CD-6000F

CD-6000F fluorescence fully automatic chemiluminescence imaging system, 6.05 million pixels, -60°C cooled CCD, equipped with 6 sets of RGB light sources and multiple filters, supports chemiluminescence, multi-color fluorescence and nucleic acid/protein gel imaging, and is suitable for Western Blot and other experiments.

86-15688870591
cedric@cedriccn.com
Description

Imaging Software Features:

·Preview function, which allows for pre exposure in advance. If the sample intensity is high, images can be directly taken;

·Automatic exposure shooting, no need to adjust other parameters such as exposure time, just click on shooting to obtain perfect images, which is more convenient and fast;

·The software is with automatic image optimization function, automatical adjust the histogram;

·The grayscale of the image can be manually adjusted on the shooting interface, with the save function;

·Predefined parameter settings, storage path can be set in advance, black and white reverse, horizontal reverse, and vertical reverse can be set;

·The temperature of the CCD can be set;

·Image management function, which can achieve black and white inversion, mark stacking functions, and manually adjust color levels, and save modified images.

 

Software Features:

User-friendly, fully Chinese imaging operation interface.

Software includes encryption functionality to enhance the security of experimental data.

Direct control over digital CCD and zoom lens, including exposure time, aperture, and focus.

ECL mode for ECL imaging, supporting timed or continuous shooting.

Image editing and processing functions, including editing, deleting, pasting, copying, adding text/ symbols, rotating, negative effects, and black-and-white inversion.

Capable of imaging and analyzing DNA/RNA stained with various dyes, protein gel electrophoresis, as well as chemiluminescence/chemifluorescence samples such as ECL and ECL Plus. Supports imaging and analysis of Western, Northern, Southern blots, hybrid membranes, colonies, and fluorescence analysis.

Real-time automatic exposure function to assist in obtaining the best image quality.

 

 

CCD Parameters:

Resolution: 6.05 million pixels, with 1x1, 2x2, and 4x4 pixel binning capabilities.

Pixel Size: 4.5μm × 4.5μm.

Image Resolution: Horizontal 600 DPI / Vertical 600 DPI.

Features automatic exposure functionality; 16-bit acquisition depth.

Cooling temperature down to -60°C, with controllable cooling.

Readout Noise: 4-6 e- RMS @ 12 MHz.

Full Well Capacity: 18,000 e-.

Dark Current: <0.01 e-/pixel/sec @ -25°C.

Exposure Time: 0.1 ms to 6000 seconds.

Non-linearity: <1%.

Quantum Efficiency: 95% (at 590 nm).

Lens: Imported optical fixed-focus lens, F0.85, large aperture with high light transmission.

White Light Reflection Lamp: LED white light reflection, adjustable brightness.

UV Transilluminator: 22×22 cm, 302 nm.

Excitation Light Source: 6 sets of RGB fluorescence light sources.

Filters: 590 nm, 535 nm, 605 nm, 699 nm.

6-Position Motorized Filter Wheel.

Door Mechanism: Sliding drawer design with strong dark box sealing.