Tel:86-15688870591 E-mail:cedric@cedriccn.com
Atomic Absorption Spectrophotometer CD-3604AA/CD-3608AA
Atomic Absorption Spectrophotometer CD-3604AA/CD-3608AA

CD-3604AA/3608AA atomic absorption spectrophotometer, single-beam total reflection optical system, deuterium lamp and self-absorption double background correction, equipped with 4/8 lamp holder. Supports flame/graphite furnace analysis, fully automatic control, professional software including 6 calibration methods, complete data, comprehensive safety protection, suitable for trace metal element detection.

86-15688870591
cedric@cedriccn.com
Description

Product Features:

·Total internal reflection optical system.

·Comprehensive and safe intelligent gas control module, full-band deuterium lamp background correction technology and high-performance self-absorption dual background correction.

·Fully automatic instrument control, light source supports high-performance element lamps, one-button quick operation.

·Eight-lamp stand with 360-degree rotation design.

·Equipped with an atomizer and intelligent lifting.

·Simple, professional, automatic, and fully operable RG-WinAAS workstation software under MS Windows system.

·QA/QC function: Submits SD and RSD of the abs. for each test, and provides SD and RSD of the calculated concentration. The working curve of the test standard sample automatically checks the correlation coefficient.

·Full information measurement: Saves the results of each measurement using different data processing methods (average, peak height, peak area, and statistical results) for user analysis.

·The workstation software can save and output various data and graphical materials, and supports data processing.

·Six calibration equations: Provides six linear and nonlinear concentration calibration methods. 11. The database allows for quick and easy configuration of wavelength, spectral bandwidth, lamp current, negative high voltage, energy balance, and other parameters with a single click.

 

Product Specification: 

Model

CD-3604AA

CD-3608AA

Optical system

Instrument Type

Single beam

Monochromator

Aberration-corrected C-T type, focal length 350mm

Dispersive Element

grating 1200 lines/mm, scintillation wavelength 250nm

Spectral Bandwidth (nm)

0.10.20.40.71.42nm

Wavelength Range (nm)

190-900

Wavelength Indication Error

±0.3 nm

±0.2 nm

Wavelength Repeatability (nm)

≤0.1nm

≤0.1nm

Spectral Bandwidth Deviation

±0.02 nm

±0.02 nm

Lamp Position

4

8

Element Lamp Type

Standard elemental lamp

Standard elemental lamp

Photometric
performance

Reading methods

Transmittance, Absorbance, Concentration

Transmittance, Absorbance, Concentration

Photometric range

0-125%, -0.1-3.00A

0-125%, -0.1-3.00A

Cu static baseline drift

±0.004A/30min

±0.003A/30min

Cu dynamic baseline drift

±0.006A/15min

±0.005A/15min

Background correction

Deuterium lamp background
correction capability >=30 times (1Abs)

Deuterium lamp >= 40 times (1Abs)

Atomization system

Single Flame Furnace

Flame Analysis

Characteristic Concentration (Cu)

≤0.04ug/ml

≤0.035ug/ml

Detection Limit (Cu)

≤0.008ug/ml

≤0.006ug/ml

Repeatability

RSD≤1%

RSD≤0.6%

Acetylene Flow Regulation

12-speed automatic

12-speed automatic

Air Assist Gas Regulation

4-speed automatic

4-speed automatic

Burner Lifting

Manual lifting

Automatic lifting

Burner

Titanium burner

Sprayer

High-efficiency glass atomizer

Atomizing Chamber

Corrosion-resistant atomization chamber

Safety Measures

Flame and combustion gas/auxiliary gas abnormal pressure protection

Graphite Furnace
Analysis

Characteristic Quantities

Cd≤1pg
Cu≤22pg

Cd≤0.8pg
Cu≤20pg

Detection Limit

Cd≤1.5pg
Cu≤20pg

Cd≤1.0pg
Cu≤10pg

Repeatability (Cd)

RSD≤4%

RSD≤3%

Graphite Furnace Heating Range

Room temperature ~ 3000℃

High-Power Heating Range

1500℃ ~ 3000℃

Ramp and Holding Time

1s ~ 255s

Heating Rate

Maximum heating rate 2000℃/second

Atomization Heating Method

Light-controlled heating, time-controlled heating, normal heating

External Protective Gas Flow Rate

1 L/min

Internal Protective Gas Flow Rate

4 adjustable levels (0, 50, 200, 250/min flow rate)

Safety Measures

Cooling water flow rate, protective gas pressure, furnace body temperature,
 power supply temperature, and graphite tube installation alarm.

Data
processing

Measurement Method

Flame emission method, graphite furnace method, hydride generation-atomic
absorption spectrometry, flame emission method

Concentration Calculation
 Method

Standard curve method (6 linear and nonlinear fitting methods),
standard addition method, interpolation method

Number of Repeat Measurements

Calculate and provide the average, standard deviation, and
relative standard deviation of absorbance and concentration for 1-30 trials.

Report Printing

Parameter printing, data result printing

Other

Dimensions

830*650*560

830*650*560

Weight (kg)

90Kg

90Kg

Power Requirements

220V, 50Hz

Operating Temperature

10℃~30℃

Operating Humidity

40%~85%